T1 - Comparison of folate quantification in foods by high-performance liquid chromatography-fluorescence detection to that by stable isotope dilution assays using high-performance liquid chromatography-tandem mass spectrometry
AU - Freisleben, Achim
AU - Schieberle, Peter
AU - Rychlik, Michael
PY - 2003/4/15
Y1 - 2003/4/15
N2 - A comparison study on folate quantitation was carried out between the recently developed stable isotope dilution assay using liquid chromatography-tandem mass spectrometry (LC-MS-MS) and the frequently used HPLC with fluorimetric detection (LC-FD). By applying LC-MS-MS, spinach, wheat bread, beef, and blood plasma were found to contain 159.2, 19.8, 1.2, and 5.6μg/100g total folates, respectively, whereas the respective quantitative data obtained by LC-FD were 95.5, 16.2, 0.7, and 6.8μg/100g. In all samples, LC-MS-MS revealed superior selectivity and precision and circumvented the shortcomings of conventional LC techniques, i.e., ambiguous peak assignment as well as high detection limits for 5-formyltetrahydrofolate, 10-formylfolic acid, and folic acid. The affinity chromatography columns used in this study showed excellent cleanup performance and permitted detection limits as low as 0.1, 0.5, 0.1, 0.08, and 0.1μg/100g for tetrahydrofolate (H4folate), 5-methyl-H4folate, 5-formyl-H4folate, 10-formylfolate, and pteroylglutamic acid, respectively. Thus, a 10-fold higher sensitivity compared to solid-phase anion-exchange cartridges was achieved. However, affinity chromatography columns revealed a significantly higher affinity toward the natural vitamers than to the racemic isotopomeric standards, which has to be considered when applying the latter in stable isotope dilution assays.
AB - A comparison study on folate quantitation was carried out between the recently developed stable isotope dilution assay using liquid chromatography-tandem mass spectrometry (LC-MS-MS) and the frequently used HPLC with fluorimetric detection (LC-FD). By applying LC-MS-MS, spinach, wheat bread, beef, and blood plasma were found to contain 159.2, 19.8, 1.2, and 5.6μg/100g total folates, respectively, whereas the respective quantitative data obtained by LC-FD were 95.5, 16.2, 0.7, and 6.8μg/100g. In all samples, LC-MS-MS revealed superior selectivity and precision and circumvented the shortcomings of conventional LC techniques, i.e., ambiguous peak assignment as well as high detection limits for 5-formyltetrahydrofolate, 10-formylfolic acid, and folic acid. The affinity chromatography columns used in this study showed excellent cleanup performance and permitted detection limits as low as 0.1, 0.5, 0.1, 0.08, and 0.1μg/100g for tetrahydrofolate (H4folate), 5-methyl-H4folate, 5-formyl-H4folate, 10-formylfolate, and pteroylglutamic acid, respectively. Thus, a 10-fold higher sensitivity compared to solid-phase anion-exchange cartridges was achieved. However, affinity chromatography columns revealed a significantly higher affinity toward the natural vitamers than to the racemic isotopomeric standards, which has to be considered when applying the latter in stable isotope dilution assays.
KW - Electrospray mass spectrometry
KW - Folates
KW - LC-MS-MS
KW - Stable isotope dilution assay
UR - https://www.scopus.com/pages/publications/0037446436
U2 - 10.1016/S0003-2697(03)00029-0
DO - 10.1016/S0003-2697(03)00029-0
M3 - Article
C2 - 12689834
AN - SCOPUS:0037446436
SN - 0003-2697
VL - 315
SP - 247
EP - 255
JO - Analytical Biochemistry
JF - Analytical Biochemistry
IS - 2